Filter Results By:

Products

Applications

Manufacturers

Showing results: 1441 - 1455 of 2604 items found.

  • 2000-6000W AC power source

    CX-P2KW - Shenzhen Chuangxin Instruments Co., Ltd.

    The AC power source is made by adopting microcomputer processing chip and high power device. It provides a stable pure sine wave and has voltage, over current, over temperature, overload protection. It can output 0-300V adjustable voltage, and 45-70Hz adjustable frequency as well as fixed frequency as 50 Hz or 60 Hz, 100 Hz and 200 Hz and 400 Hz. This AC power source can simulate power grid of different countries, provide a stable voltage, frequency, waveform which can be used to test and age the exprot products and provide kinds of precision tests for laboratory, measuring room, etc.

  • Audio Multimeter

    AMM-1 - D'Amore Engineering llc

    The purpose of this tool is to enable the user to: Measure True Amplifier Power output into any load reactive or resistive Measure Common DC voltages Measure DC voltage drops during quick transients on cable runs or battery / charging systems Measure Impedance of speakers at any power or frequency from 20Hz - 1kHz (box rise) Measure Phase Difference between Voltage and Current into reactive loads (Power Factor) Find Tuning Frequency of subwoofer enclosures Tune subwoofer enclosures for maximum power transfer Measure AC Volts (amplifier output) Measure AC Amps (amplifier output)

  • "Stiff Grid" and Parallel Operation AC Generator Excitation Regulator

    SVRFP - Kinetics Industries

    The Kinetics model SVRFP Exciter/Regulator rectifier is designed and rated in capacity and operating parameters for the application of exciting the fields on an AC generator in parallel with other AC generators and the power system is a "stiff system" in relation to loading. A "stiff system" is a generating system that is of sufficient capacity or the generator is "small" in relation to the system grid, that the AC system voltage under impulse/step loading condition does not require forcing of the generator field to maintain the power grid voltage. Systems are designed with a standard unit service factor to operate within the +10% to -20% nominal voltage rating at 100% current rating.

  • Digital LOOP/PSC/LOAD Tester

    2811 LP - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Displays and sound warning if external voltage present.● Displays mains voltage, scroll trough menus.● Checks wiring integrity (LEDs and display).● Single button operation.● Auto-off/auto-ranging.● Combined prospective short circuit current, PSC and LOOP tester.● Built-in carry case, test leads in separate pouch.● Loop test for L-E and L-N and PSC.● Voltage test L-N and L-E.● Enables analysis of constituent components in L-E and L-N loops giving resistance of earth, neutral wire, live wire and transformer winding.● Display can be customized for special orders.● 60Hz available on request.

  • Portable Electricity Meter Testers

    EE-120A-3S - EMSYST Ltd

    The EE-120A-3S unit consists of a three-phase energy standard class 0.1 and current load up to 120A. The unit performs testing of all types of electricity meters using the voltages of the network. The meter error can be measured for active, reactive or apparent energy in Manual Mode or with predefined Test Plans using the keyboard and the LCD display on the panel. Maximum Demand Test, Register Test, Starting Current Test and No Load Test can be performed too. The energy standard of the system can be used without the phantom load to test meters with customer load and perform analysis of the three-phase network – with direct measurement or with optional current clamps.

  • ±6 kV ANSI/ESDA/JEDEC 2-Pin HBM Tester

    HBM-S1-B - High Power Pulse Instruments GmbH

    *±6 kV Human-Body-Model (HBM) 2-pin tester according ANSI/ESDA/JEDEC JS-001 standard with C = 100 pF, R = 1.5 kΩ discharge network*True HBM: the classical discharge network of the HBM-S1-A according the standard ensures compliant waveforms for all load conditions*Optionally available upgrade for all HPPI TLP-3010C, 4010C, 8010A, and 8010C hardware systems and software (upgrade on request)*Suppression of trailing pulses*Integrated 10 kΩ charge removal resistor*Integrated DUT voltage and DUT current sensor for real time voltage and current monitoring*Integrated DC test DUT switchIntegrated hardware 50 Ω trigger output for high speed digital oscilloscopesIntegrated overvoltage protection of voltage sense and DC test interfaces for oscilloscope and SMU protection during high voltage HBM testing*Fast and efficient HBM measurements including transient waveform data management using the HPPI TLP software*Compact size 145 mm x 82.5 mm x 44 mm

  • Current Sense Amplifiers

    Analog Devices Inc.

    Analog Devices’ current sense amplifiers offer excellent performance for a wide array of automotive and power management applications. These devices accurately amplify small voltages in the presence of large common-mode voltage, and provide high bandwidth, as well as level shifting and bidirectional capability. Excellent dc and ac accuracy over a wide temperature range from –40°C to +125°C minimizes errors in your measurement loop while not sacrificing on cost and package size.

  • Digital Clampmeters

    Meco Instruments Pvt. Ltd.,

    AC Current 40A, 400A, 1000A AC Voltage 4V, 40V, 400V, 750V (Auto) (40-500Hz) DC Voltage 4V, 40V, 400V, 1000V (Auto) Resistance 400Ω, 4KΩ, 40KΩ, 400KΩ, 4MΩ, 40MΩ (Auto) Frequency 10.00 Hz, 50.00 Hz, 500.0 Hz, 5.000 KHz, 50.00KHz, 500.0 KHz(Auto) Sp. Functions Data Hold, Audible Continuity, Diode Test, APO Jaw Opening 43mm Max.

  • Digital Panel Meter

    DC - Laurel Electronics, Inc

    Laureate DC voltage and current panel meters with a DC signal conditioner board combine high accuracy with high read rate and a wide range of isolated output options for computer interface and control. Accuracy is 99.99% of full scale 1 count. Used as a direct-reading DC voltmeter, the Laureate provides a full-scale readout of 20,000 counts and six full-scale voltage ranges from 200.00 mV with 10 mV resolution to 600.0 V with 100 mV resolution.

  • High Voltage Linear Power Supplies Bipolar 4-quadrant, Analog/Digital/Local Control, Ultra Low Ripple/Noise

    Series BOP-HV - Kepco, Inc.

    The Kepco Model BOP 500DM and BOP 1000DM are high voltage power sources, up to 500V or 1000V, respectively. These combine the capabilities of fast programmable power supplies with a Class A output stage, which can respond bidirectionally from zero. The BOP-HV can be operated in either a "voltage stabilizing" or "current stabilizing" operating mode (selectable by a front panel switch). These power supplies offer ultra low noise and ultra low ripple at the output and are MIL-STD-461 compliant.

  • PXI-2586, 10-Channel, 12 A, SPST PXI Relay Module

    778572-86 - NI

    10-Channel, 12 A, SPST PXI Relay Module—The PXI‑2586 is a general-purpose switch module that features independent single‑pole single‑throw (SPST) Form A armature relays. Each relay has low contact resistance and high isolation voltage. The PXI‑2586 is fully software programmable. It is rated for both high currents and high voltages, so it is ideal for switching power signals and loads in control applications and battery, power supply, and automotive testing.

  • GPS, GLONASS, Galileo Micro Splitter 2 Way, SMA, 1176.45 - 1602.00 MHz, 50 Ohm, Passive

    GPSL12 - INSTOCK Wireless Components, Inc

    GPSL12 is a two way, passive, GPS signal splitter ideal for splitting a GPS antenna signal between two receivers while providing a DC current path to power remotely located active GPS antennas from the receivers. Maximum voltage rating is 50 VDC; max current rating is 1000 mA. Furnished with SMA female connectors all ports. Being a "micro-sized" splitter, GPSL12 weighs only 21 grams and is suitable for applications requiring low-weight parts.

  • Photometric Radiometric Transmitters

    HD2021T6 / HD2021T7 - Delta OHM S.r.L.

    The transmitters allow converting the photometric quantity “equivalent veiling luminance” – HD2021T7 – or a photometric quantity Luminance (cd/m2) – HD2021T6 – into a current (4…20 mA) or a voltage (0…10 V) signal according to the version chosen. If the acquisition station is far from the probe (>50m), it is necessary to use the current output version.The probe is used for the control of street lighting, in particular, the measurement of equivalent veiling luminance is essential to determine the threshold luminance at the entrance of the tunnels (UNI 11095:2011).

  • Regenerative AC load function

    61800 Series Optional Function - Chroma ATE Inc.

    The regenerative AC load function consists of various modes such as CC Rectified mode, CP Rectified mode, CR mode, CC Phase lead/lag mode and CP Phase lead/ lag mode. The Rectified Mode is capable of simulating non-linear rectified loads with characteristics similar to Chroma 63800 series AC load where the voltage and current operate at the 1st and 3rd quadrant. The Rectified Mode supports both CC and CP functions with current, power and CF as parameter settings.

  • Generator Insulation Resistance Tester

    WA2660 - Wuhan Sangao Electrical Test Installations Limit Co.

    WA2660 series insulation resistance testing instrument is special use for internal water cooling generator's measurement test. Meanwhile, can also be used in laboratory or field insulation test.The output current is greater than 25mA,Maximum output voltage is 2500V.With high precision micro current measurement system, digital boost system.Only need a high-voltage line and a signal line connecting the sample can be measured.Automatic measurement, the results from the large screen liquid crystal display, and the results are stored.

Get Help